Share

Seismic Performance of Corroded Reinforced Concrete Structures Retrofitted with FRP

Download Seismic Performance of Corroded Reinforced Concrete Structures Retrofitted with FRP PDF Online Free

Author :
Release :
Genre :
Kind : eBook
Book Rating : 846/5 ( reviews)

GET EBOOK


Book Synopsis Seismic Performance of Corroded Reinforced Concrete Structures Retrofitted with FRP by : Dejian Shen

Download or read book Seismic Performance of Corroded Reinforced Concrete Structures Retrofitted with FRP written by Dejian Shen. This book was released on . Available in PDF, EPUB and Kindle. Book excerpt:

Retrofitting of Concrete Structures by Externally Bonded FRPs, With Emphasis on Seismic Applications

Download Retrofitting of Concrete Structures by Externally Bonded FRPs, With Emphasis on Seismic Applications PDF Online Free

Author :
Release : 2006-01-01
Genre : Technology & Engineering
Kind : eBook
Book Rating : 758/5 ( reviews)

GET EBOOK


Book Synopsis Retrofitting of Concrete Structures by Externally Bonded FRPs, With Emphasis on Seismic Applications by : fib Fédération internationale du béton

Download or read book Retrofitting of Concrete Structures by Externally Bonded FRPs, With Emphasis on Seismic Applications written by fib Fédération internationale du béton. This book was released on 2006-01-01. Available in PDF, EPUB and Kindle. Book excerpt: fib Bulletin 35 is the first bulletin to publish documentation from an fib short course. These courses are held worldwide and cover advanced knowledge of structural concrete in general, or specific topics. They are organized by fib and given by internationally recognized experts in fib, often supplemented with local experts active in fib. They are based on the knowledge and expertise from fib's ten Commissions and nearly fifty Task Groups. fib Bulletin 35 presents the course materials developed for the short course "Retrofitting of Concrete Structures through Externally Bonded FRP, with emphasis on Seismic Applications", given in Ankara and Istanbul in June 2005. The course drew on expertise both from outside Turkey and from the large pool of local experts on this subject. In most countries of the world, the building stock is ageing and needs continuous maintenance or repair. Moreover, the majority of existing constructions are deficient in the light of current knowledge and design codes. The problem of structural deficiency of existing constructions is especially acute in seismic regions, as, even there, seismic design of structures is relatively recent. The direct and indirect costs of demolition and reconstruction of structurally deficient constructions are often prohibitive; furthermore they entail a substantial waste of natural resources and energy. Therefore, structural retrofitting is becoming increasingly widespread throughout the world. Externally bonded Fibre Reinforced Polymers (FRPs) are rapidly becoming the technique of choice for structural retrofitting. They are cleaner and easier to apply than conventional retrofitting techniques, reduce disruption to the occupancy and operation of the facility, do not generate debris or waste, and reduce health and accident hazards at the construction site as well as noise and air pollution in the surroundings. fib Bulletin 35 gives state-of-the-art coverage of retrofitting through FRPs and presents relevant provisions from three recent standardisation milestones: EN 1998-3:2005 "Eurocode 8: Design of structures for earthquake resistance - Part 3: Assessment and retrofitting of buildings", the 2005 Draft of the Turkish seismic design code, and the Italian regulatory document CNR-DT 200/04, "Instructions for Design, Execution and Control of Strengthening Interventions by Means of Fibre-Reinforced Composites" (2004).

Inelastic Structural Response and FRP Retrofitting of Reinforced Concrete Core Walls

Download Inelastic Structural Response and FRP Retrofitting of Reinforced Concrete Core Walls PDF Online Free

Author :
Release : 2018
Genre :
Kind : eBook
Book Rating : /5 ( reviews)

GET EBOOK


Book Synopsis Inelastic Structural Response and FRP Retrofitting of Reinforced Concrete Core Walls by : Hamid Arabzadeh

Download or read book Inelastic Structural Response and FRP Retrofitting of Reinforced Concrete Core Walls written by Hamid Arabzadeh. This book was released on 2018. Available in PDF, EPUB and Kindle. Book excerpt: The use of C-shaped reinforced concrete (RC) core walls as the main lateral force resisting system for building structures is a popular choice for medium- to high-rise buildings. These cores are typically closed on three sides (C-shaped) and are either open or partially open on the fourth side. Despite the frequent use of C-shaped RC core walls as the primary seismic force resisting system (SFRS) for multi-story buildings, there are still challenges in estimating their inelastic seismic response, whether they are separate or coupled C-shaped walls. The eccentricity between the centre of mass and the centre of rigidity tends to induce a significant torsional seismic demand on such walls. To address this issue, several design codes have proposed recommendations for evaluating the effect of this eccentricity. Although National Building Code of Canada (NBCC, 2015) specifies provisions to consider the accidental eccentricity and the torsional sensitivity of the structure in the design, there is a gap in the knowledge of the inelastic structural response of C-shaped RC core walls for new buildings. On the other hand, many existing RC C-shaped walls are in need for retrofitting in order to meet current seismic design codes, or to meet increased demands due to change in the use and occupancy of the building, or to retrofit post-earthquake damages. In recent years, application of fibre-reinforced polymer (FRP) composites in retrofitting of RC walls has considerably increased due to its advantages such as high strength to weight ratio and its fast and easy installation. The objectives of this thesis are to: (i) investigate, numerically, the effectiveness of FRP retrofitting on the seismic performance of RC shear wall systems, (ii) evaluate the deficiency of seismic design provisions of C-shaped shear wall structures with high torsional sensitivity, (iii) examine, experimentally, the seismic response of FRP-retrofitted C-shaped RC walls to quantify the efficiency of the FRP retrofitting in repairing the RC core walls. To achieve the first objective, a simplified modelling approach was proposed for analyzing the FRP retrofitted RC walls in order to be used as a simple and efficient method in practice. Nonlinear Incremental Dynamic Analysis (IDA) of a typical twelve story RC building structure, following the FEMA P695 methodology, showed that although the increase of torsional sensitivity has no significant effect on the inter-story drift ratios of the building, it could significantly decrease the Collapse Margin Ratio (CMR). To achieve the second objective, building structures with different levels of height and torsional sensitivity were studied. Results showed that although response spectrum analysis (RSA) provides consistent predictions for story shear demand in regular buildings, significant underestimation of design forces might be obtained for buildings with a torsional sensitivity of B ≥ 2.0. Dual Plastic Hinge (DPH) method was found to be an efficient alternative in reducing the story shear demand in structures with high torsional sensitivity, compared to structures designed based on the common Single Plastic Hinge (SPH) method. To achieve the third objective, a previously tested large-scale C-shaped RC wall was retrofitted using carbon fibre-reinforced polymer (CFRP) composite sheets and was tested under the same condition and loading protocol of the original wall to quantify the efficacy of FRP retrofitting on the wall's response. Furthermore, multi-directional cyclic tests were conducted in order to evaluate the complete nonlinear response of the FRP retrofitted C-shaped wall up to failure. The assessment was based on experimental measurements and observations in terms of 3D displacements, strains (both from strain gauges and Digital Image Correlation, DIC, system), crack pattern, ductility, curvature profiles and mode of failures. The test showed that the FRP retrofitting scheme used in the current work performed very well by enhancing both the strength and ductility of the retrofitted wall from its damaged state, while holding its stiffness very close, compared to those of the control wall.

Seismic Assessment and Retrofit of Reinforced Concrete Buildings

Download Seismic Assessment and Retrofit of Reinforced Concrete Buildings PDF Online Free

Author :
Release : 2003-08-01
Genre : Technology & Engineering
Kind : eBook
Book Rating : 642/5 ( reviews)

GET EBOOK


Book Synopsis Seismic Assessment and Retrofit of Reinforced Concrete Buildings by : fib Fédération internationale du béton

Download or read book Seismic Assessment and Retrofit of Reinforced Concrete Buildings written by fib Fédération internationale du béton. This book was released on 2003-08-01. Available in PDF, EPUB and Kindle. Book excerpt: In most parts of the developed world, the building stock and the civil infrastructure are ageing and in constant need of maintenance, repair and upgrading. Moreover, in the light of our current knowledge and of modern codes, the majority of buildings stock and other types of structures in many parts of the world are substandard and deficient. This is especially so in earthquake-prone regions, as, even there, seismic design of structures is relatively recent. In those regions the major part of the seismic threat to human life and property comes from old buildings. Due to the infrastructure's increasing decay, frequently combined with the need for structural upgrading to meet more stringent design requirements (especially against seismic loads), structural retrofitting is becoming more and more important and receives today considerable emphasis throughout the world. In response to this need, a major part of the fib Model Code 2005, currently under development, is being devoted to structural conservation and maintenance. More importantly, in recognition of the importance of the seismic threat arising from existing substandard buildings, the first standards for structural upgrading to be promoted by the international engineering community and by regulatory authorities alike are for seismic rehabilitation of buildings. This is the case, for example, of Part 3: Strengthening and Repair of Buildings of Eurocode 8 (i. e. of the draft European Standard for earthquake-resistant design), and which is the only one among the current (2003) set of 58 Eurocodes attempting to address the problem of structural upgrading. It is also the case of the recent (2001) ASCE draft standard on Seismic evaluation of existing buildings and of the 1996 Law for promotion of seismic strengthening of existing reinforced concrete structures in Japan. As noted in Chapter 1 of this Bulletin, fib - as CEB and FIP did before - has placed considerable emphasis on assessment and rehabilitation of existing structures. The present Bulletin is a culmination of this effort in the special but very important field of seismic assessment and rehabilitation. It has been elaborated over a period of 4 years by Task Group 7.1 Assessment and retrofit of existing structures of fib Commission 7 Seismic design, a truly international team of experts, representing the expertise and experience of all the important seismic regions of the world. In the course of its work the team had six plenary two-day meetings: in January 1999 in Pavia, Italy; in August 1999 in Raleigh, North Carolina; in February 2000 in Queenstown, New Zealand; in July 2000 in Patras, Greece; in March 2001 in Lausanne, Switzerland; and in August 2001 in Seattle, Washington. In October 2002 the final draft of the Bulletin was presented to public during the 1st fib Congress in Osaka. It was also there that it was approved by fib Commission 7 Seismic Design. The contents is structured into main chapters as follows: 1 Introduction - 2 Performance objectives and system considerations - 3 Review of seismic assessment procedures - 4 Strength and deformation capacity of non-seismically detailed components - 5 Seismic retrofitting techniques - 6 Probabilistic concepts and methods - 7 Case studies

Seismic Strengthening of Concrete Buildings Using FRP Composites

Download Seismic Strengthening of Concrete Buildings Using FRP Composites PDF Online Free

Author :
Release : 2008
Genre : Concrete construction
Kind : eBook
Book Rating : 134/5 ( reviews)

GET EBOOK


Book Synopsis Seismic Strengthening of Concrete Buildings Using FRP Composites by :

Download or read book Seismic Strengthening of Concrete Buildings Using FRP Composites written by . This book was released on 2008. Available in PDF, EPUB and Kindle. Book excerpt: "This CD-ROM consists of eight papers that were presented by ACI Committee 440 at the Spring Convention in Atlanta, GA, in April 2007"--Site Web de l'éditeur

You may also like...